Industry requires a continuous check of production to assure its compliance.
Pentatec supplies a fully automatic system Quality control system for tankers for liquid CO2/Oxygen/Argon/Nitrogen to manage the complete process of road-tanker loading under quality control which assures:
- the control of the automatic filling sequence for liquid CO2/N2/Ar/O2 in transportable tanks;
- the analysis of residual impurities in the road- tank to be filled;
- the analysis of the product loaded (in connection with the CO2/N2/Ar/O2 analysis system);
- the print out of delivery bill and quality certificate.
How the system works
When a road- tank arrives it is recognized by the driver badge. As soon as flexible hoses are connected, the analysis of the road-tank starts to avoid any product contamination. If everything is OK, the system fills the tank truck in a closed loop configuration. If not, the truck is filled in open loop mode. Once completed the filling, the system prints out the Liquid CO2 certificate of analysis and the Bill of Loading. The system can also be connected to the Factory truck weighing system.